Skip to content

We use Google Analytics cookies to learn which content helps dentists. You decide. How we use cookies

Clinical insight · Digital workflow

Photogrammetry vs intraoral scanning for full-arch implants

What photogrammetry captures on a full-arch implant case, how it compares with an intraoral scanner, what clinical studies show and what to send the lab.

By Equipe técnica Smile Digital LabUpdated 5 min read

Short answer

Photogrammetry records implant positions with cameras and dedicated scan bodies carrying optical targets. On full arches, systematic reviews find it more accurate than intraoral scanning, especially in angulation. It does not capture soft tissue, teeth or the bite, so the case still needs an intraoral scan or an impression.

What is dental implant photogrammetry?

Dental implant photogrammetry records implant positions with cameras, reading dedicated scan bodies with optical targets screwed onto the implants or abutments. In extraoral systems, two stereo cameras photograph all the targets at once and calculate each implant’s position and angulation relative to the others.

The output file holds those coordinates and nothing else. Some systems run photogrammetry through the intraoral scanner itself; the review by Revilla-León and colleagues (The Journal of Prosthetic Dentistry, 2026) groups it with the calibrated techniques for full-arch implant scanning.

Why does intraoral scanning lose accuracy on a full arch?

Intraoral scanning loses accuracy across a full arch because the scanner builds the model by stitching consecutive images, and every join adds a little error. On a long edentulous ridge with few stable landmarks, that error adds up. Extraoral photogrammetry skips the stitching and captures every scan body in a single shot.

In the review by Pozzi and colleagues (Clinical Implant Dentistry and Related Research, 2025), intraoral scanning went past 1° of angular deviation, the threshold linked to passive fit, in all three studies that measured angles. Photogrammetry stayed between 0.24° and 0.80°. Scan technique is still in your hands; the steps are in our guide on how to scan a full arch for an implant bridge.

Photogrammetry or intraoral scanning: which is more accurate?

Photogrammetry was more accurate than intraoral scanning in most of the full-arch implant systematic reviews published in 2025 and 2026. The edge shows up in both trueness and precision, linear and angular. Most of the underlying studies are in vitro, and the authors want clinical trials before a firm conclusion.

reviewstudies includedwhat it found
Pozzi et al., Clin Implant Dent Relat Res, 202513 (3 clinical, 10 in vitro)photogrammetry more accurate in 10 of 13; intraoral angulation above 1° in the 3 that measured it
Altalla et al., J Prosthet Dent, 202614, in vitro and clinicalbetter trueness and precision with photogrammetry, linear and angular
Noronha et al., Int J Prosthodont, 202611 in vitro, 7 meta-analyzedphotogrammetry more precise and more consistent; trueness data carried little weight
Prasad et al., J Prosthet Dent, 202626 on extraoral photogrammetrymean discrepancy of 27 µm and 0.21°; clinically acceptable
Revilla-León et al., J Prosthet Dent, 202615 on calibrated techniquesintraoral photogrammetry at 36 µm and 0.23° on average; significant publication bias
Alfaraj et al., J Prosthodont, 202637 (30 in vitro, 7 clinical)digital and conventional equivalent overall; above four implants, impressions had a slight edge, and photogrammetry narrowed the gap

In the Revilla-León review, every calibrated technique stayed under 150 µm, the distortion threshold the authors treat as clinically acceptable. What the table doesn’t measure is how much the difference changes the bridge in the mouth, and few clinical studies address that.

Are there clinical results for bridges made from photogrammetry?

Yes, in short series. In the retrospective multicenter study by Stefanović and colleagues (Journal of Dentistry, 2026), 52 full-arch bridges on 221 implants, made from intraoral photogrammetry, passed the one-screw test at delivery. At about 12 months, prosthesis survival was 100%.

Zhang and colleagues (The Journal of Prosthetic Dentistry, 2023) compared photogrammetry with splinted conventional impressions in 14 arches. Mean deviation was 70 µm, under the 150 µm threshold, and grew with the distance between implants.

In the randomized pilot trial by Peñarrocha-Diago and colleagues (2017), with immediate loading in 18 patients, photogrammetry and conventional impressions did not differ in implant success, marginal bone loss or prosthesis survival.

Which technique takes less chair time?

Intraoral scanning was the fastest technique in the clinical study by Robert and colleagues (International Journal of Oral Implantology, 2026), with 20 edentulous patients and four to eight implants each. Photogrammetry and plaster impressions took longer in the chair, and patients rated both digital techniques above the conventional impression.

In the same study, photogrammetry had the lowest error: 0.030 mm root mean square error, against 0.117 mm for the intraoral scanner and 0.110 mm for plaster. Against conventional impressions, it shortened the appointment in the Peñarrocha-Diago trial (15.6 vs 20.5 minutes). Remember to count the intraoral scan that photogrammetry still needs.

What doesn’t photogrammetry capture?

Photogrammetry doesn’t capture soft tissue, the ridge, teeth, emergence profiles or the bite: its file holds implant positions only. The case also needs an intraoral scan or an impression, which the technician aligns with the camera file. The review by Negreiros and colleagues (Australian Dental Journal, 2025) also lists the cost of the device.

what the lab needsintraoral scanningphotogrammetry
implant positionsscan bodies in the scanthe camera file, with the system’s scan bodies
soft tissue and ridgesame scana separate intraoral scan, or an impression
teeth, provisional and bitesame scana separate intraoral scan
scan body model on the Rxyour scanner’sthe photogrammetry system’s and your scanner’s

Source: Pozzi et al. (2025) and Negreiros et al. (2025).

Before your first photogrammetry case, ask the lab whether it takes the camera file, in which format, and how it wants the matching intraoral scan: both have to open in the same design software. Everything else on the Rx, from implant brand and platform to the scanned provisional, is in the full-arch scanning guide.

When does photogrammetry make the biggest difference?

Photogrammetry makes the biggest difference when the arch has many implants or widely spaced ones. In the meta-analysis by Alfaraj and colleagues (Journal of Prosthodontics, 2026), digital accuracy dropped above four implants, and photogrammetry appeared to offset the drop. In the Zhang clinical study (2023), deviation grew with inter-implant distance.

The choice of technique is yours. Whichever you use, Pozzi and colleagues recommend a rigid prototype try-in until clinical trials catch up. That applies to any rigid definitive bridge, such as a milled titanium bar or a full-arch zirconia bridge.

Smile Digital Lab, a digital dental lab in São Paulo, Brazil, makes full-arch bridges in zirconia, zirconia on a titanium bar or PMMA, with Neodent and Titaniumfix components, both made in Brazil. We check every case when it arrives and on eight points before it ships. The options are on our implant restorations page.

Related services

Open a portal account

Frequently asked questions

Does photogrammetry make the bar try-in unnecessary?

There's no evidence to skip it. Pozzi and colleagues (2025) recommend a rigid prototype try-in until clinical trials catch up. In a 2026 retrospective series, all 52 bridges made from intraoral photogrammetry passed the one-screw test, but that is one study, one system and about a year of follow-up.

Can photogrammetry be used for immediate loading?

Yes. The review by Negreiros and colleagues (2025) describes it in both immediate and delayed loading. In the randomized pilot trial by Peñarrocha-Diago and colleagues (2017), with 18 immediate-load patients, photogrammetry and conventional impressions did not differ in implant success or prosthesis survival.

Does smartphone photogrammetry work?

There's one early clinical study. On 10 arches with six multi-unit abutments, Santamaría-Laorden and colleagues (2026) found a mean difference of 21 µm and 0.20° between a phone app and the same company's photogrammetry device. It compared the two with each other, not with the true implant positions.

Do I need special scan bodies for photogrammetry?

Yes. Photogrammetry reads optical targets on the system's own scan bodies, screwed onto the implants or abutments. The intraoral scan that goes with the case uses your scanner's scan bodies. Put both models on the Rx.

Sources

  1. Photogrammetry versus intraoral scanning in complete-arch digital implant impression: a systematic review and meta-analysis · Clinical Implant Dentistry and Related Research (Pozzi et al., 2025)
  2. Comparative accuracy of photogrammetry and intraoral scanners in recordings for complete arch implant-supported prostheses: a systematic review and meta-analysis · The Journal of Prosthetic Dentistry (Altalla et al., 2026)
  3. Accuracy of stereophotogrammetry in implant scanning compared to intraoral scanning in completely edentulous patients — a systematic review and meta-analysis · The International Journal of Prosthodontics (Noronha et al., 2026)
  4. A systematic review and meta-analysis of the accuracy of complete arch implant scanning techniques performed extraorally: reverse impression and extraoral photogrammetry methods · The Journal of Prosthetic Dentistry (Prasad et al., 2026)
  5. Accuracy of complete arch implant scans recorded by using calibrated scanning techniques: a systematic review and meta-analysis · The Journal of Prosthetic Dentistry (Revilla-León et al., 2026)
  6. Comparative analyses of accuracy between digital and conventional impressions for complete-arch implant-supported fixed dental prostheses — a systematic review and meta-analysis · Journal of Prosthodontics (Alfaraj et al., 2026)
  7. Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: a retrospective multicentre study on 35 patients · Journal of Dentistry (Stefanović et al., 2026)
  8. Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: a comparative clinical study · The Journal of Prosthetic Dentistry (Zhang et al., 2023)
  9. A combined digital and stereophotogrammetric technique for rehabilitation with immediate loading of complete-arch, implant-supported prostheses: a randomized controlled pilot clinical trial · The Journal of Prosthetic Dentistry (Peñarrocha-Diago et al., 2017)
  10. Precision, patient satisfaction and impression time with complete-arch digital implant impression with intraoral scanning, dental photogrammetry and conventional impressions: an experimental clinical study · International Journal of Oral Implantology (Robert et al., 2026)
  11. Photogrammetry in implant dentistry · Australian Dental Journal (Negreiros et al., 2025)
  12. Accuracy of a smartphone app and photogrammetry algorithm in complete arch digital implant capture: an in vivo comparative study · The Journal of Prosthetic Dentistry (Santamaría-Laorden et al., 2026)

One technical letter a month

Materials, protocols and what we see at the bench. No promotions, and you can leave anytime.

Keep reading

WhatsApp