Guide · Full-arch
How to scan a full arch for an implant bridge
A scan sequence for full-arch implant bridges, the scan body errors that cost you passive fit, and when to ask for a verification jig or bar try-in.
Short answer
A full-arch implant scan for a fixed bridge brings together the provisional in the mouth with the opposing arch and bite, the soft tissue without scan bodies, the scan bodies on every abutment and the provisional out of the mouth. Every scan body has to be complete and fully seated. Check them in the software before the patient leaves.
Step by step
- 01
Scan the provisional in the mouth, with the bite
With the provisional screwed in at the vertical dimension you approved, scan the arch with it in place, the full opposing arch and a buccal bite scan on both sides. You're done when the arches line up in the software with no overlap or gap.
- 02
Scan the soft tissue without the provisional
Remove the provisional and, with the abutments in place and no scan bodies yet, scan the whole ridge. This is the tissue reference for the intaglio of the bridge.
- 03
Seat the scan bodies
Use the scan body made for each abutment system, with no wear, dings or trimming, tightened per the manufacturer. Make sure every one is fully seated before you start.
- 04
Scan the scan bodies
Follow the scan path your scanner's manufacturer recommends for edentulous arches. Capture every scan body in full, top and sides, and the tissue between them without breaks.
- 05
Check every scan body in the software
Rotate the model and check each scan body: complete geometry, no holes, no doubled image and no tissue over the base. If one failed, delete that section and rescan it before the patient leaves.
- 06
Scan the provisional out of the mouth
Scan the whole provisional, intaglio and all surfaces. It carries the tooth and gingival volume the patient has already tested into the design.
- 07
Export and attach to the order
Export all the files and attach them to the portal order with implant brand and platform, the cuff height and angle of each abutment, and the scan body model. Note on the order whether there will be a try-in before the definitive.
What do you need before you scan a full arch?
Before you scan a full arch, have three things settled. The tooth and bite reference, usually the provisional the patient is wearing and you have approved. The abutments, with brand, platform, cuff height and angle of each one noted for the order. And a scan body from the right system for every abutment.
The provisional is the prototype of the definitive bridge: it holds the occlusion and vertical dimension that already work in the mouth. An and colleagues (The Journal of Prosthetic Dentistry, 2018) describe a digital technique that carries that information from the provisional to the definitive without a stone cast. That’s why it gets scanned twice, in the mouth and out of it.
Use the scan body as it came out of the package, with no wear or trimming. Petchmedyai and Thanasrisuebwong (PLOS One, 2023) advise against modifying scan bodies, because the CAD software may stop matching them to its library. The model matters too: in an in vitro study by Meneghetti and colleagues (PLOS One, 2023), with six implants on multi-unit abutments, seven scan bodies and four scanners produced different accuracy.
Why does the scan body decide passive fit?
The scan body decides passive fit because the software calculates each implant position from its surface in the file. In a full-arch bridge, every one of those positions goes into a single rigid framework: one implant off in the file becomes a bar or a zirconia bridge that seats under strain.
The margin is small. Pozzi and colleagues’ systematic review (Clinical Implant Dentistry and Related Research, 2025) treats a misfit under 150 µm and up to 1° of angular deviation as generally enough to avoid complications like screw loosening. In some of the in vitro studies in that review, mean angular deviation with intraoral scanning went past 1°.
Two in vitro studies show where the error comes from. Petchmedyai and Thanasrisuebwong (PLOS One, 2023) exposed the scan body at 8, 5.3 and 2.7 mm and deleted part of the image. The largest mean error, 0.24° and 0.08 mm, came with the least exposure and the incomplete image.
Matta and colleagues (International Journal of Implant Dentistry, 2026) built up gingiva over the scan bodies in two steps of about 3 mm and cut defects into them. Every error increased deviation: 30 µm in the best group with lower tissue, 178 µm in the worst with higher tissue.
Both studies used one- and three-implant models rather than full arches, but the lesson carries over: expose as much of the scan body as you can and leave no gaps in the mesh.
Which scan errors send a full-arch case back?
Each of these errors starts in the scan or on the order, and each one takes a quick check before the patient leaves.
| error | what happens to the bridge | how to avoid it |
|---|---|---|
| Scan body with missing geometry or a doubled image | the implant position shifts in the design, and the bridge seats under strain or with a gap | check every scan body in the software and rescan that section on the spot |
| Tissue covering the base of the scan body | angular and positional error, larger the less scan body shows | expose as much of the scan body as you can; if you can’t, consider an impression with impression copings |
| Loose or partly seated scan body | the file shows the implant where it isn’t | check seating and tightening on each one before you scan |
| Worn, trimmed or wrong-system scan body | the software can’t match the image to the component library | use the scan body made for the system, unmodified, and put the model on the order |
| Bite taken without the provisional, or on one side only | teeth and vertical dimension designed with no reference; the bridge can come back high or low | scan the provisional in the mouth with a buccal bite on both sides |
| Provisional not scanned out of the mouth | the design loses the tooth and gingival volume the patient approved | scan the whole provisional, intaglio included |
| Partial opposing arch | contacts and occlusion designed with no reference | scan the full opposing arch |
| Abutment brand, platform, cuff height or angle missing from the order | wrong component and a bridge that doesn’t fit | list every abutment on the order |
How do you record the bite on an edentulous patient?
On an edentulous patient, record the full-arch bite with the provisional screwed in: it holds the vertical dimension and contacts you approved, and a buccal scan on both sides carries that relationship into the file. The same provisional, scanned out of the mouth, gives the technician the tooth form.
Without a fixed provisional, the reference has to come from somewhere else: the denture the patient wears, if you have approved its vertical dimension, or a record base with a wax rim. Agree with the lab on which one when you open the case. Immediate loading follows a different logic, with the scan taken right after surgery; our article on what the lab needs for immediate loading covers it.
Scan bodies or impression copings?
Scan bodies and impression copings both work for a full arch, and the choice is yours. In the systematic review by Gehrke and colleagues (International Journal of Implant Dentistry, 2024), scan bodies matched conventional impressions for single units and short spans. For full arches, there weren’t enough clinical data for a recommendation.
The meta-analysis by Pesce and colleagues (Journal of Clinical Medicine, 2025) pooled 9 clinical full-arch studies. The results conflict, but most put prostheses made from scans within clinically acceptable limits.
For scans, Gehrke’s review lists what changes accuracy: scan body design, material and color, scanner type, technique, scan aids, inter-implant distance, scan span and number of implants. The case brings some of these; technique and scan body choice are yours.
If the implant is deep and the scan body ends up covered, an impression with impression copings is the alternative. Send the copings or analogs with the order; we digitize the cast at the lab, and the design follows the same digital workflow.
Does photogrammetry replace intraoral scanning?
Photogrammetry doesn’t fully replace intraoral scanning. It’s an extraoral camera that records implant positions from dedicated scan bodies with optical targets, but it doesn’t capture gingiva, ridge or teeth, so the case still needs an intraoral scan or an impression.
In the Pozzi review (2025), covering 13 studies (3 clinical, 10 in vitro), photogrammetry was more accurate than intraoral scanning in 10 of the 13. The authors call for clinical trials before drawing conclusions. If you use photogrammetry, ask the lab before the first case how to send the camera files alongside the intraoral scan. The other reviews, the clinical studies and the chair time of each technique are in our article on photogrammetry vs intraoral scanning for full-arch implants.
When should you ask for a verification jig or bar try-in?
A try-in makes sense when the definitive is rigid and full-arch, like a milled titanium bar or a full-arch zirconia bridge. It’s what Pozzi and colleagues (2025) recommend: until clinical trials settle full-arch scan accuracy, try in a rigid prototype before the final prosthesis.
A verification jig is a rigid index that splints the implants in their recorded position; a bar try-in does the same job with the bar itself. In both, use the one-screw test (the Sheffield test): tighten only one terminal screw and look for rocking or gaps at the other abutments, then repeat from the other end.
Eid and colleagues (BMC Oral Health, 2026) used this test on a four-implant model, with the terminal screw at 15 Ncm, to measure the gap at the other three under titanium bars. Milled bars averaged 49 µm and printed bars 44 µm, both clinically acceptable. A try-in is there to find the gap while it can still be fixed; agree on it when you open the case.
The full try-in sequence, the other passive-fit tests and what to do when the bar won’t seat are in our framework try-in guide.
What does the lab check when the file arrives?
Smile Digital Lab, a digital dental lab in São Paulo, Brazil, making restorations for oral rehabilitation, checks at intake that the file opens and is complete, with every scan body readable, before the case moves on to design. If a scan body isn’t readable, the case stops there and we come back to you rather than design on a doubtful position.
We check every case when it arrives and on eight points before it ships, and you follow its phase in the portal (the screens are in Portuguese). We use Neodent and Titaniumfix components, both made in Brazil; if your system is different, put brand and platform on the order. The bridges themselves are on our zirconia on titanium bar page and full-arch zirconia page, and file basics are in our intraoral scanning guide.
Checklist before you send
- Provisional scanned in the mouth, with the full opposing arch and a bite on both sides
- Soft tissue scanned without scan bodies
- Every scan body complete, fully seated and clear of tissue at the base
- Provisional scanned out of the mouth, intaglio included
- Implant brand and platform, cuff height and angle of each abutment, scan body model
- Bar or prototype try-in agreed, when the definitive is rigid
Related services
Open a portal accountFrequently asked questions
Can I use the immediate-load scan for the definitive bridge?
It's not the safest route. For the definitive, take a new scan with scan bodies on the abutments once the tissue is stable, and scan the provisional in and out of the mouth. The provisional brings what already worked into the final bridge: tooth position, occlusion and vertical dimension.
Do I need to send the scan body to the lab?
No. Put the scan body brand and model on the order: the design software uses that component's digital library to locate each implant. If it's an uncommon model, check with the lab before you scan the first case.
Is scanning faster than an impression for a full arch?
In the clinical studies pooled by Ma and colleagues (2023), full-arch scanning took 8.6 minutes less than a conventional impression on average, and every prosthesis in the studies with one to two years of follow-up was still in function. The authors urge caution, since some of the data come from the same research group.
Sources
- A systematic review of factors impacting intraoral scanning accuracy in implant dentistry with emphasis on scan bodies · International Journal of Implant Dentistry (Gehrke et al., 2024)
- Photogrammetry versus intraoral scanning in complete-arch digital implant impression: a systematic review and meta-analysis · Clinical Implant Dentistry and Related Research (Pozzi et al., 2025)
- Accuracy of full-arch intraoral scans versus conventional impression: a systematic review with a meta-analysis and a proposal to standardise the analysis of the accuracy · Journal of Clinical Medicine (Pesce et al., 2025)
- Accuracy of digital implant impressions obtained using intraoral scanners: a systematic review and meta-analysis of in vivo studies · International Journal of Implant Dentistry (Ma et al., 2023)
- Optimizing digital implant impressions: evaluating the significance of scan body image deficiency and alignment under varied scan body exposures · PLOS One (Petchmedyai and Thanasrisuebwong, 2023)
- Impact of scanning errors on the trueness of digital implant impressions · International Journal of Implant Dentistry (Matta et al., 2026)
- Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: an in vitro study · PLOS One (Meneghetti et al., 2023)
- Passive fit of milled and additively manufactured complete arch implant-supported titanium frameworks: a micro-CT analysis · BMC Oral Health (Eid et al., 2026)
- A CAD-CAM technique for conversion of interim-to-definitive restoration in patients with complete edentulism · The Journal of Prosthetic Dentistry (An et al., 2018)
One technical letter a month